Personlized Products Touch Screen Module - AC/DC Medical Adapter ADA360K240S001A – DWIN Detail:
Video
Specification
Selection
Max. Power | 36W |
Input voltage | 100-240 VAC |
Voltage/Current | DC24V /1500mA |
Efficiency | 90% |
Max. Capacitive Load | 2000 uF |
Standby Power Consumption | 0.075W |
Input Parameters
Input Voltage Range | AC input: 100-240VAC |
Input Frequency | 50-60Hz |
Input Current | 115VAC, Max. 0.7A 230VAC, Max. 0.5A |
Impulse Current | 115VAC, Typic: 10A 230VAC, Typic: 25A |
Leakag current | 264VAC/60Hz, typic: 0.1mA |
Output Paremeters
Output Voltage Accuracy | Typic: ±5% |
Linear Regulation Rate | Full load, typic: ±0.5% |
Load Regulation Rate | Typic: ±1% |
Ripple Noise | 20MHz, Typic: 50mV, Max. 100mV |
Temperature Drift Coefficient | Typic: ± 0.02%/℃ |
Short Circuit Protection | Long term short circuit, self recovery |
Over Current Protection | ≥130% IO self recovery |
Over Voltage Protection | 12V output: ≤27VDC 24V output: ≤40VDC |
Standby Power | Max. 0.075W |
Minimum Load | Min. 0% |
Power Down Hold Time | 115VAC input: typic 15ms 230VAC input: typic 80ms |
General Parameters
Isolation Voltage(Input/Output) | Min. 4000VAC(The test time is 1 minute, and the leakage current is ≤ 5mA) |
Orerating Temp. | -40/+70℃ |
Storage Temp. | -40/+85℃ |
Storage Humidity | 95%RH |
Wave Soldering | 260±5℃; time: 5-10S |
Manual Welding | 360±10℃; time: 3-5S |
Switching Frequency | 65kHz |
Safety Standards | EN60601-1 |
Safety Certification | EN60601-1 |
Safety Level | 2XMOPP(Primary side-Secondary side) |
Mean Time Between Failure | ≥300000H (25%) |
EMC Parameters
Conducted Disturbance | EN55011(CISPR11)/EN55032(CISPR32) CLASSB |
Radiation Disturbance | EN55011(CISPR11)/EN55032(CISPR32) CLASSB |
Voltage Flicker | EN61000-3-2 |
Harmonic Current | EN61000-3-2 |
ESD | ±8KV/Contact ±2KV, 4KV, 8KV, 15KV/Air |
Radiated Immunity | 10V/m |
Burst Immunity | ±2KV |
Surge Immunity | ±0.5KV/±1KV |
Conducted Disturbance Immunity | 3Vm/0.15MHz-80MHz 6Vm(Within 15m band) /0.15MHz-80MHz 80%AM,1kHz |
Immunity to voltage sags, sags and short interruptions | 0%UT 0.5cycle 0°,45°,90°,135°,180°, 270°,315°。 0%UT 1cycle 70%UT 25/30 cycle 0° 0%UT 250/300 cycle |
Application
Product detail pictures:

Related Product Guide:
With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and growth, we're going to build a prosperous future together with your esteemed firm for Personlized Products Touch Screen Module - AC/DC Medical Adapter ADA360K240S001A – DWIN, The product will supply to all over the world, such as: Tunisia , Manila , New Delhi , We always insist on the management tenet of Quality is first, Technology is basis, Honesty and Innovation.We are able to develop new products continuously to a higher level to satisfy different needs of customers.

Excellent provider! All the orders always on time, good deal and high-quality devices.