Personlized Products Touch Screen Module - AC/DC Medical Adapter ADA360K240S001A - DWIN


Specification

Product Tags

Related Video

Feedback (2)

Bear Customer initially, High quality first in mind, we do the job closely with our customers and supply them with efficient and skilled providers for Ips Android Lcm , External Touch Screen Monitor , Tft 2.5 , We have now designed a reputable track record among many shoppers. Quality&customer initially are normally our constant pursuit. We spare no attempts to produce greater solutions. Stay up for long-term cooperation and mutual positive aspects!
Personlized Products Touch Screen Module - AC/DC Medical Adapter ADA360K240S001A – DWIN Detail:

Video

Specification

适配器主图
Selection

Max. Power 36W
Input voltage 100-240 VAC
Voltage/Current DC24V /1500mA
Efficiency 90%
Max. Capacitive Load 2000 uF
Standby Power Consumption 0.075W

Input Parameters

Input Voltage Range AC input: 100-240VAC
Input Frequency 50-60Hz
Input Current 115VAC, Max. 0.7A
230VAC, Max. 0.5A
Impulse Current 115VAC, Typic: 10A
230VAC, Typic: 25A
Leakag current 264VAC/60Hz, typic: 0.1mA

Output Paremeters

Output Voltage Accuracy Typic: ±5%
Linear Regulation Rate Full load, typic: ±0.5%
Load Regulation Rate Typic: ±1%
Ripple Noise 20MHz, Typic: 50mV, Max. 100mV
Temperature Drift Coefficient Typic: ± 0.02%/℃
Short Circuit Protection Long term short circuit, self recovery
Over Current Protection ≥130% IO self recovery
Over Voltage Protection 12V output: ≤27VDC
24V output: ≤40VDC
Standby Power Max. 0.075W
Minimum Load Min. 0%
Power Down Hold Time 115VAC input: typic 15ms
230VAC input: typic 80ms

General Parameters

Isolation Voltage(Input/Output) Min. 4000VAC(The test time is 1 minute, and the leakage current is ≤ 5mA)
Orerating Temp. -40/+70℃
Storage Temp. -40/+85℃
Storage Humidity 95%RH
Wave Soldering  260±5℃; time: 5-10S
Manual Welding 360±10℃; time: 3-5S
Switching Frequency 65kHz
Safety Standards EN60601-1
Safety Certification EN60601-1
Safety Level 2XMOPP(Primary side-Secondary side)
Mean Time Between Failure ≥300000H (25%)

EMC Parameters

Conducted Disturbance EN55011(CISPR11)/EN55032(CISPR32) CLASSB
Radiation Disturbance EN55011(CISPR11)/EN55032(CISPR32) CLASSB
Voltage Flicker EN61000-3-2
Harmonic Current EN61000-3-2
ESD ±8KV/Contact
±2KV, 4KV, 8KV, 15KV/Air
Radiated Immunity 10V/m
Burst Immunity ±2KV
Surge Immunity ±0.5KV/±1KV
Conducted Disturbance Immunity 3Vm/0.15MHz-80MHz 6Vm(Within 15m band) /0.15MHz-80MHz 80%AM,1kHz
Immunity to voltage sags, sags and short interruptions 0%UT 0.5cycle 0°,45°,90°,135°,180°, 270°,315°。 0%UT 1cycle 70%UT 25/30 cycle 0° 0%UT 250/300 cycle

Application

工业级别应用图片共用 商业级别应用图片共用


Product detail pictures:

Personlized Products  Touch Screen Module -
 AC/DC Medical Adapter ADA360K240S001A  – DWIN detail pictures


Related Product Guide:

With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and growth, we're going to build a prosperous future together with your esteemed firm for Personlized Products Touch Screen Module - AC/DC Medical Adapter ADA360K240S001A – DWIN, The product will supply to all over the world, such as: Tunisia , Manila , New Delhi , We always insist on the management tenet of Quality is first, Technology is basis, Honesty and Innovation.We are able to develop new products continuously to a higher level to satisfy different needs of customers.
  • Good customer relationship, on time dispatch and good quality products. staffs are always ready for technical supports.
    5 Stars By Sabina from Jersey - 2017.12.31 14:53
    Excellent provider! All the orders always on time, good deal and high-quality devices.
    5 Stars By Roxanne from South Korea - 2018.12.14 15:26

    Related Products